F.O. cable 50/125 OM4 Out.PE-Metallic armoured
Optical Fiber

| Fiber Details | |
| Type | 10G-550 |
| Core diameter | 50,0 ±2.5µm |
| Cladding diameter | 125,0 ±1.0µm |
| Core non-circularity | ≤5,0% |
| Cladding non-circularity | ≤1,0% |
| Core-Cladding concentricity error | ≤1,5µm |
| Coating diameter | 242 ±5µm |
| Coating non-circularity | ≤6,0% |
| Cladding-Coating concentricity error | <12µm |
| OFL Bandwidth | 850nm ≥3500 MHz/km – 1300nm ≥500 MHz/km |
| Effective Modal Bandwidth | 850nm ≥4700 MHz/km – 1300nm ≥500 MHz/km |
| Attenuation coefficient | 850nm ≤3,50 dB/km – 1300nm ≤1,50 dB/km |
| Costruction Characteristics | |
| Tubes | 1 |
| Diameter of tube | 2,80mm ±0.15mm |
| Loose tube material | PBT |
| Loose tube color | Natural |
| Colored Coating Fiber | dimension: 250µm±15µm
color: blue, orange, green, brown, grey, white, red, black, yellow, violet, pink, aqua green |
| Strength member | Glass Yarn |
| PSP (Armoured) | 17mm (model number) |
| Diameter | 7,70mm ±0.3mm |
| Environmental and mechanical Perfomances | |
| Long term tension | 240N |
| Short term tension | 700N |
| Long term crush | 300N/10cm |
| Short term crush | 1000N/10cm |
| Min. bending radius (static lay) | 15 x Diam. ex. |
| Min. bending radius (dynamic lay) | 20 x Diam. ex. |
| Operating temperature/storage | -30°C ~ +70°C |
| Laying temperature/installation | -10°C ~ +50°C |
| Outer sheath | |
| Type | PE Black |
| Printing | ECS – Number FO OM4 50/125 OUTDOOR Pe Fca ORDER NR. METER MARKING |
| Tests | Rules | Value | Approval parameters |
| Traction | IEC 60794-1-21-E1 | 480N | Δα ≤0,25 dB/km – Fiber draw ratio ≤0,45% |
| Crush | IEC 60794-1-21-E3 | 1000N/100mm (maximum 15 minutes) | Δα ≤0,05 dB – No damage |
| Crash | IEC 60794-1-21-E4 | 4.5 Nm, 3 impacts, R= 300mm | Δα ≤0,05 dB |
| Torque | IEC 60794-1-21-E7 | 100N, ±180° 10 cycles | Δα ≤0,05 dB – No damage |
| Repeated bending | IEC 60794-1-21-E11 | 20xD., 1Kg, 3 cycles | Δα ≤0,05 dB – No damage |
| Bending radius | IEC 60794-1-21-E6 | R=20xD., 4 turns, 3 cycles | Δα ≤0,05 dB – No damage |
| Temperature cycling | IEC 60794-1-22-F1 | -20°C ~ +70°C | Maximum value 0,05 dB/km |
| Smart code | Item number | Nr Fibers | Diameter mm. | Weight Kg/Km | Min.bending radius |
| AR-FOM4-12 | AR-FOPEFM12EXM4NEB40 | 12 | 7,7mm | 60.00 | 15xExt.Diam. |

}
The details expressed above have to be considered as an indication.
European Cable Service S.r.L. - Tel. +39 0583 436283 - www.europeancableservice.it - info@europeancableservice.it