S/FTP CAT 6 4x2xAWG26 LSZH
LAN Cables
| Construction |
|
| Conductor |
Flexible 7×0.16 mm Bare CU |
| Insulation |
FMPE 1.06 ±0.05mm |
| First Shield |
single pair Al/PET |
| Second Shield |
Tinned CU Braid >40% |
| Outer sheath |
LSZH Grey Diam. 6,30±0.2mm |
| Printing |
ECS-S/FTP CAT 6 4x2x26AWG LSZH EIA/TIA 568 ISO/IEC 11801 CEI-UNEL 36762 C-4 (Uo=400V) WW/YY [ORDER N.] 001m – Eca |
| Electrical properties |
|
| Conductor resistance |
<93,80 Ω/Km a 20°C |
| CC Ring resistance |
<26,0 Ω/100m a 20°C |
| Mutual capacitance |
43 pF/m |
| Standard impedance |
100±15Ω tra 1MHz e 100MHz |
| Min bending radius |
60 mm |
| Operating temperature |
-20°C +60°C |
| Rules |
Applications |
| IEC 61156-5 |
ISDN |
| EIA/TIA 568 |
TPDDI |
| ISO/IEC 11801 |
ATM |
| EN 50173 |
10/100BASE-T (IEEE 802.3) |
| EN-50288-5-1 |
1000BASE-T 10GBASE-T |
| Notes |
| The installation of this cable guarantees more immunity against electromagnetic noises, reduction of emission of radio interferences, reduction of dual aphonia if applied to single pairs. |
| Frequency(MHz) |
RL(dB) |
ATT(dB/100m) |
Next(dB/100m) |
PS.Next(dB/100m) |
Elfext(dB/100m) |
PS.Elfext(dB/100m) |
| 1 |
20.00 |
3.00 |
74.30 |
72.30 |
67.80 |
64.80 |
| 4 |
23.00 |
5.70 |
65.30 |
63.30 |
55.80 |
52.80 |
| 10 |
25.00 |
9.00 |
59.30 |
57.30 |
47.80 |
44.80 |
| 16 |
25.00 |
11.40 |
56.20 |
54.20 |
43.70 |
40.70 |
| 20 |
25.00 |
12.80 |
54.80 |
52.80 |
41.80 |
38.80 |
| 31.25 |
24.00 |
16.10 |
51.90 |
49.90 |
37.90 |
34.90 |
| 62.5 |
22.00 |
23.10 |
47.40 |
45.40 |
31.90 |
28.90 |
| 100 |
20.00 |
29.70 |
44.30 |
42.30 |
27.80 |
24.80 |
| 200 |
18.00 |
43.50 |
39.80 |
37.80 |
21.80 |
18.80 |
| 250 |
17.30 |
49.20 |
38.30 |
36.30 |
19.80 |
16.80 |
| Smart code |
Item number |
N° pairs x section AWG |
Diameter mm. |
Weight Kg/Km |
| LT-626 |
LSHFR64A26FXGRB03 |
4x2xAWG26 |
6,30 ±0.2 |
43.00 |
}
The details expressed above have to be considered as an indication.
European Cable Service S.r.L. - Tel. +39 0583 436283 - www.europeancableservice.it - info@europeancableservice.it